Ravi Palle VillaAntharam · Chevella · lighting study

Two-storey · east-facing square villa · concept for review

Walk the rooms. Find every light point.

Step through a room-by-room 3D concept, orbit to inspect the walls and ceiling, and compare fixture ideas with the electrical plan. The geometry is schematic; verify all points and clearances on site.

08 fan symbols in the electrical book LP wall/light point noted at 2.6 m from FFL CLP ceiling-light provision, use selectively East-facing orientation follows the plan set
Room-by-room virtual tourChoose a room, then drag to look around and scroll to zoom
Ground floor · Living & dining

Drag to orbit · scroll or pinch to zoom · choose rooms above

The 3D view is unavailable in this browser. Choose rooms above to review their points, or use the floor plan view.

Choose a room above, then drag and pinch to inspect it.

Proposed wall fixture group Fan point shown on plan Optional shallow ceiling feature

Schematic room geometry, not a measured model. Fixture positions are interpretive; use the electrical plan and site dimensions for setting-out.

Drawing basis

RP 03 SQUARE VILLA.pdf: A101 ground floor, A102 first floor and false-ceiling layouts. Book 11 Oct 2026.pdf: ground/first-floor electrical plans and wall electrical legend. The legend marks wall/light points, ceiling-light provisions, fan locations and mounting levels.

What the site photos confirm

Photos show plain finished walls, switch plates, ceiling drops and window positions. They help choose compact wall fittings and avoid clashes; they do not establish fixture counts or electrical point heights.

Unfinished villa wall with installed switch plate and electrical point
Switchboard and wall finish: keep the sconce body clear of the switch plate.
Ceiling with an exposed electrical drop before the light fitting is installed
Ceiling rough-in: fans must be slab-fixed; keep optional POP shallow.
Large window opening toward the planted garden
Garden-facing glazing: shield outdoor light to limit glare into the room.

First-pass shopping direction

Buy the fans first. Final-count the wall lights in the rooms.

Fan symbols are legible in the electrical book; decorative wall-fixture quantity is a design allowance, not a fixture schedule. Keep the sconce count tied to existing LPs, then add only the few CLP/false-ceiling accents you choose.

  • Quiet BLDC ceiling fans · 1,200 mm8 plan points
  • Shielded indoor wall lights · 3,000 Kmatch LPs
  • Mirror lights · high-CRI · IP44 near basinby vanity
  • Outdoor wall lights · sealed · IP65by terrace
  • Kitchen / wardrobe LED profiles · CRI 90cut to fit
  • Optional deep-recessed accents · 3,000 Konly at CLP